Only authenticated and authorized users with appropriate scope can invoke Create Device Dispense
Device Dispense is created in async way. Successful result of the job should return a link on the created Device Dispense (look at /wiki/spaces/CSI/pages/17467506869 ).
Device Dispense can be created only under active Device Request within valid dispense period
Several devices of different manufacturers with the same code can be dispensed at a time
Multiple dispenses to the same Device Request is not allowed
It is allowed to create Device Dispense for not active or not verified persons (for the same reasons as in the medication reimbursement process)
Specification
Page Properties | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||||||||||||
|
Logic
Fill in the following fields:
status = IN_PROGRESS
status_reason = null
subject. Set hashed patient_id from URL
performer_legal_entity. Set client_id from token
quantity.unit. Set description according to quantity code and system
inserted_at. Set current date and time
updated_at. Set current date and time
inserted_by. Set current user from token
updated_by. Set current user from token
Save data to device_dispenses collection in MongoDB according to /wiki/spaces/CSI/pages/17467572335
Send
StatusChangeEvent