Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Note

Сторінка знаходиться в процесі розробки. Інформація на ній може бути застарілою.

Info

/wiki/spaces/EN/pages/17591304241 (remove the link block before publishing the document)

Table of Contents

Properties of a REST API method document

Page Properties
idpage_properties_method_REST API

Document type

Метод REST API

Document title

[DRAFT] Get equipment details by ID [API-007-002-002-0235]

Guideline ID

GUI-0011

Author

@

Document version

1

Document status

DRAFT

Date of creation

ХХ.ХХ.ХХХХ (дата фінальної версії документа – RC або PROD)

Date of update

ХХ.ХХ.ХХХХ (дата зміни версії)

Method API ID

API-007-002-002-0235

Microservices (namespace)

ME

Component

Devices and equipment

Component ID

COM-007-002

Link на API-специфікацію

https://ehealthmisapi1.docs.apiary.io/#reference/public.-medical-service-provider-integration-layer/equipment/get-equipment-details-by-id

Resource

{{host}}/api/equipment/{{id}}

Scope

equipment:read

Protocol type

REST

Request type

GET

Sync/Async

Sync

Public/Private

Public

Purpose

N/A

Logic

  1. Only authenticated and authorized HR, ADMIN, OWNER employees from MSP, OUTPATIENT, PRIMARY_CARE, EMERGENCY legal entities can get the equipment by id.

  2. Service returns only equipment related to the same legal entity as the user. User with role NHS ADMIN can get any equipment from any legal entity.

Configuration parameters

N/A

Dictionaries

N/A

Input parameters

Input parameter

Mandatory

Type

Description

Example

1

id

 

String

Equipment identifier.

Required

d290f1ee-6c54-4b01-90e6-d701748f0851

2

Request structure

See on API-specification

Expand
titleExample
Code Block

Headers

Headers

Request data validation

Authorize

  1. Verify the validity of access token

    1. Return 401 in case validation fails

  2. Check scopes in order to perform this action (scope = 'equipment:read')

    1. Return 403 in case invalid scope(s)

Validate equipment

  1. Check that equipment with such ID exists in the system (is_active = true)

    1. In case of error - return 404

  2. Check that equipment with such ID belongs to to the same legal entity as the user OR user has NHS ADMIN role.

    1. In case of error - return 403

Processing

N/A

Response structure examples

See on API-specification

Expand
titleExample
Code Block
{
  "meta": {
    "code": 200,
    "url": "https://example.com/resource",
    "type": "object",
    "request_id": "6617aeec-15e2-4d6f-b9bd-53559c358f97#17810"
  },
  "data": {
    "id": "7c3da506-804d-4550-8993-bf17f9ee0402",
    "division_id": "8be63914-a278-470b-b868-1af5b9087332",
    "legal_entity_id": "483af06f-d4c6-4c9e-8d9b-680b5ef7270d",
    "type": "23143534",
    "external_id": "123-ASD-#1",
    "udi": [
      {
        "value": "IMEI 49015420323751",
        "type": "default",
        "assigner_name": "Ukrainian center of the certification"
      }
    ],
    "lot_number": "RZ12345678",
    "manufacturer": "GlobalMed, Inc",
    "manufacture_date": "1999-01-01",
    "expiration_date": "2020-01-01",
    "model_number": "NSPX30",
    "part_number": "#e30-SD",
    "version": "v1.0.1",
    "name": "Рентген апарат флюрографічній",
    "serial_number": "S/N234554",
    "note": "Технічний огляд раз на рік",
    "status": "ACTIVE",
    "is_active": true,
    "inserted_at": "2017-04-20T19:14:13Z",
    "inserted_by": "e1453f4c-1077-4e85-8c98-c13ffca0063e",
    "updated_at": "2017-04-20T19:14:13Z",
    "updated_by": "2922a240-63db-404e-b730-09222bfeb2dd"
  }
}HTTP status codes

HTTP status codes

Response code

HTTP Status code

Message

Internal name

Description

1

Базові

2

200

 Response

 

3

401

 

Access token validation failed

4

403

 

  • Invalid scope(s)

  • Validation failed

5

404

 

Validation failed

6

Специфічні

7

Post-processing processes

N/A

Technical modules where the method is used

Page Properties Report
headingsID ТМ, Статус
cqllabel = "tr-mis"