Properties of a REST API method document

Page Properties
idpage_properties_method_REST API

Document type

Метод REST API

Document title

[DRAFT] Activate equipment [API-007-002-002-0237]

Guideline ID

GUI-0011

Author

@

Document version

1

Document status

DRAFT

Date of creation

ХХ.ХХ.ХХХХ (дата фінальної версії документа – RC або PROD)

Date of update

ХХ.ХХ.ХХХХ (дата зміни версії)

Method API ID

API-007-002-002-0237

Microservices (namespace)

ME

Component

Devices and equipment

Component ID

COM-007-002

Link на API-специфікацію

Resource

{{host}}/api/equipment/{{id}}/actions/activate

Scope

equipment:write

Protocol type

REST

Request type

PATCH

Sync/Async

Sync

Public/Private

Public

Purpose

N/A

Logic

  1. Only authenticated and authorized HR, ADMIN, OWNER employees from MSP, OUTPATIENT, PRIMARY_CARE, EMERGENCY legal entities can activate equipments

  2. Only INACTIVE equipment can be activated

  3. Legal entity can activate only its own equipments

Configuration parameters

N/A

Dictionaries

N/A

Input parameters

Input parameter

Mandatory

Type

Description

Example

1

id

 

String

Equipment identifier.

Required

d290f1ee-6c54-4b01-90e6-d701748f0851

2

Request structure

See on API-specification

Expand
titleExample
Code Block

Headers

Headers

Request data validation

Authorize

  1. Verify the validity of access token

    1. Return 401 in case validation fails

  2. Check scopes in order to perform this action (scope = 'equipment:write')

    1. Return 403 in case invalid scope(s)

Check that legal entity is active (status = ACTIVE, SUSPENDED)

  1. Extract client_id from token (token.client_id == legal_entity_id)

  2. Check legal entity status (status = ACTIVE, SUSPENDED)

    1. In case of error - return 409 (Legal entity must be ACTIVE or SUSPENDED)

Validate division

Check that division is active

  1. Check division status (status = ACTIVE)

    1. In case of error - return 409 (Division must be active)

Validate equipment

  1. Check that equipment with such ID exists in the system (is_active = true)

    1. In case of error - return 404

  2. Check that equipment belongs to the same legal entity as the user

    1. In case of error - return 403

Validate transition

Only INACTIVE equipment can be activated

Available transitions

  1. INACTIVE → ACTIVE

In other cases - return 409 error with message "ACTIVE equipment cannot be ACTIVATED"

Processing

Update object in DB

1. equipments table

 

Patameter

Source

Description

status

Const: ACTIVE

By default ACTIVE for activated records

updated_at

Timestamp: now()

Get current date-time

updated_by

Token: user_id

Extract user from token

 

Save object to DB

1. equipment_status_hstr table

 

Parameter

Source

Description

Parameter

Source

Description

id

UUID

Autogenerated

equipment_id

UUID

Reference to equipments.id

status

Const: ACTIVE

By default ACTIVE for activated records

inserted_by

Token: user_id

Extract user from token

inserted_at

Timestamp: now()

Get current date-time

Response structure examples

See on API-specification

Expand
titleExample
Code Block
languagejson
{
  "meta": {
    "code": 200,
    "url": "https://example.com/resource",
    "type": "object",
    "request_id": "6617aeec-15e2-4d6f-b9bd-53559c358f97#17810"
  },
  "data": {
    "id": "7c3da506-804d-4550-8993-bf17f9ee0402",
    "division_id": "8be63914-a278-470b-b868-1af5b9087332",
    "legal_entity_id": "483af06f-d4c6-4c9e-8d9b-680b5ef7270d",
    "type": "23143534",
    "external_id": "123-ASD-#1",
    "udi": [
      {
        "value": "IMEI 49015420323751",
        "type": "default",
        "assigner_name": "Ukrainian center of the certification"
      }
    ],
    "lot_number": "RZ12345678",
    "manufacturer": "GlobalMed, Inc",
    "manufacture_date": "1999-01-01",
    "expiration_date": "2020-01-01",
    "model_number": "NSPX30",
    "part_number": "#e30-SD",
    "version": "v1.0.1",
    "name": "Рентген апарат флюрографічній",
    "serial_number": "S/N234554",
    "note": "Технічний огляд раз на рік",
    "status": "ACTIVE",
    "is_active": true,
    "inserted_at": "2017-04-20T19:14:13Z",
    "inserted_by": "e1453f4c-1077-4e85-8c98-c13ffca0063e",
    "updated_at": "2017-04-20T19:14:13Z",
    "updated_by": "2922a240-63db-404e-b730-09222bfeb2dd"
  }
}

HTTP status codes

Response code

HTTP Status code

Message

Internal name

Description

1

Базові

2

200

 Response

 

3

401

 

Access token validation failed

4

403

 

  • Invalid scope(s)

  • Validation failed

5

404

 

Validation failed

6

409

ACTIVE equipment cannot be ACTIVATED

7

409

Division must be active

8

409

Legal entity must be ACTIVE or SUSPENDED

9

409

 

Validation failed

10

Специфічні

11

Post-processing processes

N/A

Technical modules where the method is used

Page Properties Report
headingsID ТМ, Статус