Purpose
This WS is designed to revoke previously created Device request.
This method must be used to revoke existing Device Request. Method receives signed message (pkcs7) that consists of signed content, digital signature and signer public key. All signature fields will be validated (including signer certificate authority)
Specification
Logic
Save signed content to media storage
Update device request status to revoked (update also updated_at, updated_by)
Get person's authentication_method of MPI
If authentication_method == OTP:
Generate text SMS with template
TEMPLATE_SMS_FOR_REVOKE_DEVICE_REQUEST
.
Send SMS
Save internal information to corresponding DB.
Send
StatusChangeEvent
to Event Manager
Request structure
See on Apiary
Example:
Authorize
Verify the validity of access token
in case of error - return 401 (“Invalid access token”) in case of validation fails
Verify that token is not expired
in case of error - return 401 (“Invalid access token”)
Check user scopes in order to perform this action (scope = 'device_request:revoke')
return 403 (“Your scope does not allow to access this resource. Missing allowances: device_request:revoke”) in case of invalid scope(s)
Headers
Content-Type:application/json
Authorization:Bearer mF_9.B5f-4.1JqM
api-key:aFBLVTZ6Z2dON1V
Request data validation
Validate request
Return 422 with the list of validation errors in case validation fails
Validate legal entity
Check legal entity type: it has to be in me_allowed_transactions_le_types config parameter, has status = active and nhs_verified = true
in case of error return 409 "Action is not allowed for the legal entity"
Validate digital signature
Validate request is signed
in case of error - return 400 (“Invalid signed content”)
Check DS is valid and not expired
Validate that DS belongs to the user
Check that DRFO from DS and party.tax_id matches
in case of error - return 422 (“Does not match the signer drfo“)
Validate user
Revoking a Device Request is allowed for a user if he has one of the following active and approved employee that:
is an author of the Device Request (requester)
is Med_Admin from legal entity where Device Request is created
in case of error - return 409 ("Employee is not an author of device request or doesn't have required employee type")
Validate transition
Only active device request can be revoked
Get current device request status
Check that status in ('active')
in case of error - return 409 error ('Device request in status %status% cannot be revoked')
For more information look at /wiki/spaces/CSI/pages/17467441235 .
Validate revoked reason
Validate $.status_reason.code is a value from eHealth/device_request_revoke_reasons dictionary
in case of error - return 422 ("value is not allowed in enum")
Validate status
The target status value must be submitted in the order of display in the signed content (media storage)
Validate $.status is revoked
in case of error - return 422 ("value is not allowed in enum")
Validate content
Signed content must match with device request in DB in order to be revoked
Render device request from DB
Exclude $status, $.status_reason from signed content
Compare rendered device request and signed content
In case both object doesn't match - return 422 ('Signed content doesn't match with previously created device request')
Response structure
See on Apiary
Example: