ЕСОЗ - публічна документація
RC_Device & DeviceAssociation status model
Device:
Device Association:
Detected Issue:
Statuses of Device
Status | Conditions | Description | Method to turn the status |
---|---|---|---|
ACTIVE |
| The device record is current and is appropriate for reference in new instances | |
ENTERED_IN_ERROR | Active device | Final status of device. The record was entered in error and therefore nullified |
Statuses of Device Association
Status | Conditions | Description | Method to turn the status |
---|---|---|---|
IMPLANTED | Device is registering in the system | Referenced Device is implanted in patient’s body | |
EXPLANTED | Device Association with status=implanted is present | Final status of Device Association. Referenced Device is explanted from patient’s body | |
ATTACHED | Device is registering in the system OR attaching again after being unattached | Referenced Device is attached to patient | |
UNATTACHED | Device Association with status=attached is present | Referenced Device is unattached from patient | |
ENTERED_IN_ERROR | Device Association is not already in entered_in_error status | Final status of Device Association. The record was entered in error and therefore nullified |
Statuses of Detected Issue
Status | Conditions | Description | Method to turn the status |
---|---|---|---|
PRELIMINARY |
| This is an initial or interim observation: data may be incomplete or unverified. | |
MITIGATED |
| Indicates the detected issue has been mitigated | |
ENTERED_IN_ERROR | Detected Issue is not already in entered_in_error status | Final status of Detected Issue. The record was entered in error and therefore nullified |