ЕСОЗ - публічна документація
RCC_CSI-3205_Composition data model
eHealth description
Composition
Collection name: compositions
Collection is used to store composition document
Composition document
Name | Type | M/O | Description and constraints | HL7 vs eHealth comparison result |
---|---|---|---|---|
id | string | M | System identifier of Composition (ObjectID) | Doesn't comply with FHIR |
status | string | M | Composition status | Ok |
type | M | Type of composition | Ok | |
category | М | Category of composition | Ok According to FHIR - category is array | |
date | date_time | M | When the composition was signed | Ok |
title | string | M | Human Readable name/title | Ok |
subject | string | M | Hashed patient_id | Doesn't comply with FHIR (datatype) |
custodian | M | Organization which maintains the composition | Ok | |
encounter | M | Context of the Composition | Ok | |
author | M | Who and/or what authored the composition | Ok | |
section | [Section] | O | Composition is broken into sections | Ok |
extension | [Extension] | O | Extensions added to composition | Ok |
relates_to | O | Relationships to other compositions/documents | Ok | |
attester | [Attester] | M | Attests to accuracy of composition | Ok |
event | [Event] | M | The clinical service(s) being documented | Ok |
context_episode_id | string | M | Reference to episode of care | Doesn't comply with FHIR |
signed_content_links | [string] | M | Reference on signed content in media storage | Doesn't comply with FHIR |
inform_with | string | O | Hashed patient authentication method used while creating composition | Doesn't comply with FHIR |
status_reason | O | Reason code for status of the Composition (used in mark-in-error process) | Doesn't comply with FHIR | |
explanatory_letter | string | O | Description for status of the Composition (used in mark-in-error process) | Doesn't comply with FHIR |