ЕСОЗ - публічна документація

[NEW] Device & DeviceAssociation Data Model

FHIR description

  1. Device - Device - FHIR v5.0.0

  2. Device Association - DeviceAssociation - FHIR v5.0.0

  3. Detected Issue - DetectedIssue - FHIR v5.0.0

Schema

Screenshot 2024-03-19 at 10.49.48.png

Resources

Device

Collection name: devices

This collection is used to store device documents

Name

Type

M/O

Description and constraints

FHIR(v5) vs eHealth comparison

Name

Type

M/O

Description and constraints

FHIR(v5) vs eHealth comparison

id

string

M

 

System identifier of Device (ObjectID)

Ok

identifier

[Identifier]

O

 

Device identifier. Type fills from external_system dictionary

Ok

definition

{Reference}

O

 

The reference to the definition for the device

Ok

status

string

M

 

Status of Device. Dictionary device_statuses

Ok

manufacturer

string

O

 

Name of device manufacturer

Ok

manufacture_date

dateTime

O

 

Date when the device was made

Ok

expiration_date

dateTime

O

 

Date and time of expiry of this device (if applicable)

Ok

lot_number

string

O

 

Lot number of manufacture

Ok

serial_number

string

O

 

Serial number assigned by the manufacturer

Ok

name

type

array

string

M

 

M

 

Ok

value

string

M

 

Ok

model_number

string

O

The manufacturer's model number for the device

Ok

type

{CodeableConcept}

M

The kind or type of device

Ok

property

code

array

 

{CodeableConcept}

O

 

M

Dictionary device_properties

Ok

 

value[x]

 

 

One value[x] is allowed

Value[x] is required

  • value_codeable_concept

{CodeableConcept}

M

 

  • value_quantity

{Quantity}

M

 

  • value_range

{Range}

M

 

  • value_boolean

Boolean

M

 

  • value_integer

Integer

M

 

  • value_string

String

M

 

note

string

O

Device notes and comments

Ok

parent

{Reference}

O

Reference to parent device

Ok

recorder

{Reference}

M

Employee who registered device

Ok

recorder_legal_entity

{Reference}

M

Legal entity who registered device

Doesn't comply with FHIR

subject

string

M

Hashed patient_id

Doesn't comply with FHIR

context

{Reference}

M

Reference to encounter during which the record was created

Doesn't comply with FHIR

context_episode_id

uuid

M

Reference to episode of care during which the record was created

Doesn't comply with FHIR

inserted_at

timestamp

M

Datetime when Device was created

Doesn't comply with FHIR

inserted_by

string

M

User identifier who created the Device association

Doesn't comply with FHIR

updated_at

timestamp

M

Datetime when Device association was updated

Doesn't comply with FHIR

updated_by

string

M

User identifier who updated the Device association

Doesn't comply with FHIR

Device Association

Collection name:device_associations

This collection is used to store device association documents

Name

Type

M/O

Description and constraints

FHIR(v5) vs eHealth comparison

Name

Type

M/O

Description and constraints

FHIR(v5) vs eHealth comparison

id

string

M

System identifier of Device Association (ObjectID)

Ok

device

{Reference}

M

Reference to device

Ok

status

string

M

Status of Device association. Dictionary device_association_statuses

Ok

status_reason

{CodeableConcept}

O

The reasons given for the current association status

Dictionary device_association_status_reasons

Ok

subject

string

M

Hashed patient_id

Ok

body_site

{CodeableConcept}

O

Current anatomical location of the device in/on subject

Dictionary eHealth/body_structures

FHIR defines this as Reference to BodyStructure resource

association_date

date

O

Date of implantation\attachment or explantation\detachment of the device to the patient

Doesn't comply with FHIR

context

{Reference}

M

Reference to encounter during which the record was created

Doesn't comply with FHIR

context_episode_id

uuid

M

Reference to episode of care during which the record was created

Doesn't comply with FHIR

recorded

dateTime

M

The date of setting the direction of the relationship of the device to the patient

Doesn't comply with FHIR

recorder

{Reference}

M

Employee who registered device association

Doesn't comply with FHIR

recorder_legal_entity

{Reference}

M

Legal entity who registered device association

Doesn't comply with FHIR

inserted_at

timestamp

M

Datetime when Device association was created

Doesn't comply with FHIR

inserted_by

string

M

User identifier who created the Device association

Doesn't comply with FHIR

updated_at

timestamp

M

Datetime when Device association was updated

Doesn't comply with FHIR

updated_by

string

M

User identifier who updated the Device association

Doesn't comply with FHIR

Detected Issue

Collection name:detected_issues

This collection is used to store detected issue documents

Name

Type

M/O

Description and constraints

FHIR(v5) vs eHealth comparison

Name

Type

M/O

Description and constraints

FHIR(v5) vs eHealth comparison

id

string

M

System identifier of Detected Issue (ObjectID)

Ok

status

string

M

Issue status.

Dictionary detected_issue_statuses

Ok

code

{CodeableConcept}

O

Specific type of detected issue

Ok

subject

{Reference}

M

Device which issue has been detected

Ok

patient_id

string

M

Hashed patient_id. System field

Doesn't comply with FHIR

encounter

{Reference}

M

Reference to encounter during which the record was created

Ok

identified_date_time

dateTime

O

When identified

Ok

author

{Reference}

M

The employee or person who identified the issue

Ok

implicated

{Reference}

O

Device which caused an issue

Ok

detail

string

O

Description and context

Ok

recorder

{Reference}

M

The employee who registered the issue

Ok

recorder_legal_entity

{Reference}

 М

The legal entity who registered the issue

Doesn't comply with FHIR

context_episode_id

uuid

M

Reference to episode of care during which the record was created

Doesn't comply with FHIR

inserted_at

timestamp

M

Datetime when Detected issue was created

Doesn't comply with FHIR

inserted_by

string

M

User identifier who created the Detected issue

Doesn't comply with FHIR

updated_at

timestamp

M

Datetime when Detected issue was updated

Doesn't comply with FHIR

updated_by

string

M

User identifier who updated the Detected issue

Doesn't comply with FHIR

Example

devices

{ "_id" : UUID("59a5d6ed-b724-43cc-bfd7-b67028797df1"), "context" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "encounter", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("459010ca-52fc-49d2-8fc3-7e60f4d1b2ab") } }, "context_episode_id" : UUID("e8f13f2b-1522-4a7f-afd5-3a0c0fe21a23"), "definition" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "device_definition", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("b12d9f00-46ff-4aa6-8e60-cfff1bcf80e2") } }, "expiration_date" : ISODate("2020-01-01T00:00:00.000Z"), "identifier" : [ { "type" : { "coding" : [ { "code" : "default", "system" : "external_system" } ], "text" : null }, "value" : "№324-1231-ФФ" } ], "inserted_at" : ISODate("2024-03-18T14:40:12.544Z"), "inserted_by" : UUID("27f4a543-aae0-4575-b10c-ee4f4cb008f5"), "lot_number" : "RZ12345678", "manufacture_date" : ISODate("1999-01-01T00:00:00.000Z"), "manufacturer" : "GlobalMed, Inc", "model_number" : "NSPX30", "name" : [ { "type" : "user_friendly", "value" : "Смужки Accu-Chek Active для глюкометра" }, { "type" : "registered", "value" : "Тест-смужки Accu-Chek Active для глюкометра" } ], "note" : "Імплант був вилучений по причині заміни на новий", "parent" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "device", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("90a9e15b-b71b-4caf-8f2e-ff247e8a5600") } }, "property" : [ { "code" : { "coding" : [ { "code" : "default", "system" : "device_properties" } ], "text" : null }, "value_boolean" : null, "value_codeable_concept" : null, "value_integer" : null, "value_quantity" : { "code" : "kg", "comparator" : ">", "system" : "eHealth/ucum/units", "unit" : "kg", "value" : 1.5 }, "value_range" : null, "value_string" : null }, { "code" : { "coding" : [ { "code" : "default", "system" : "device_properties" } ], "text" : null }, "value_boolean" : null, "value_codeable_concept" : { "coding" : [ { "code" : "30221", "system" : "device_definition_classification_type" } ], "text" : null }, "value_integer" : null, "value_quantity" : null, "value_range" : null, "value_string" : null }, { "code" : { "coding" : [ { "code" : "default", "system" : "device_properties" } ], "text" : null }, "value_boolean" : null, "value_codeable_concept" : null, "value_integer" : 12, "value_quantity" : null, "value_range" : null, "value_string" : null }, { "code" : { "coding" : [ { "code" : "default", "system" : "device_properties" } ], "text" : null }, "value_boolean" : null, "value_codeable_concept" : null, "value_integer" : null, "value_quantity" : null, "value_range" : { "high" : { "code" : "kg", "comparator" : "<", "system" : "eHealth/ucum/units", "unit" : "kg", "value" : 2.5 }, "low" : { "code" : "kg", "comparator" : ">", "system" : "eHealth/ucum/units", "unit" : "kg", "value" : 1.5 } }, "value_string" : null }, { "code" : { "coding" : [ { "code" : "default", "system" : "device_properties" } ], "text" : null }, "value_boolean" : false, "value_codeable_concept" : null, "value_integer" : null, "value_quantity" : null, "value_range" : null, "value_string" : null }, { "code" : { "coding" : [ { "code" : "default", "system" : "device_properties" } ], "text" : null }, "value_boolean" : null, "value_codeable_concept" : null, "value_integer" : null, "value_quantity" : null, "value_range" : null, "value_string" : "some value" } ], "recorder" : { "display_value" : "СЕРГІЙ ОЛЕКСАНДРОВИЧ ПАВЛОВСЬКИЙ", "identifier" : { "type" : { "coding" : [ { "code" : "employee", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("eb794be3-e081-40ea-9ff7-e5e3f013b721") } }, "recorder_legal_entity" : { "display_value" : "Solute Med", "identifier" : { "type" : { "coding" : [ { "code" : "legal_entity", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("6e5a53bc-9c71-4c66-9cdc-37560d6dbf49") } }, "serial_number" : "NSPX30", "status" : "active", "subject" : "5E0168F480B03462A33EFD0E13C419374E681C3C1280A407612715BC019C0904", "type" : { "coding" : [ { "code" : "30221", "system" : "device_definition_classification_type" } ], "text" : null }, "updated_at" : ISODate("2024-03-18T14:40:12.544Z"), "updated_by" : UUID("27f4a543-aae0-4575-b10c-ee4f4cb008f5") }

device_associations

{ "_id" : UUID("b625c578-a2a6-4153-8c24-cbd0c311fd8f"), "association_date" : ISODate("2024-01-05T00:00:00.000Z"), "body_site" : { "coding" : [ { "code" : "head", "system" : "eHealth/body_sites" } ], "text" : null }, "context" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "encounter", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("459010ca-52fc-49d2-8fc3-7e60f4d1b2ab") } }, "context_episode_id" : UUID("e8f13f2b-1522-4a7f-afd5-3a0c0fe21a23"), "device" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "device", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("59a5d6ed-b724-43cc-bfd7-b67028797df1") } }, "inserted_at" : ISODate("2024-03-18T14:40:12.556Z"), "inserted_by" : UUID("27f4a543-aae0-4575-b10c-ee4f4cb008f5"), "recorded" : ISODate("2024-01-07T09:00:00.000Z"), "recorder" : { "display_value" : "СЕРГІЙ ОЛЕКСАНДРОВИЧ ПАВЛОВСЬКИЙ", "identifier" : { "type" : { "coding" : [ { "code" : "employee", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("eb794be3-e081-40ea-9ff7-e5e3f013b721") } }, "recorder_legal_entity" : { "display_value" : "Solute Med", "identifier" : { "type" : { "coding" : [ { "code" : "legal_entity", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("6e5a53bc-9c71-4c66-9cdc-37560d6dbf49") } }, "status" : "implanted", "status_reason" : null, "subject" : "5E0168F480B03462A33EFD0E13C419374E681C3C1280A407612715BC019C0904", "updated_at" : ISODate("2024-03-18T14:40:12.556Z"), "updated_by" : UUID("27f4a543-aae0-4575-b10c-ee4f4cb008f5") }

detected_issues

{ "_id" : UUID("f1448af5-dd29-4abb-95d4-29686b4087ee"), "author" : { "display_value" : "Олег Васильович Поплавок", "identifier" : { "type" : { "coding" : [ { "code" : "employee", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("131fe1bc-7c32-4ac1-a462-7fe25ffe98b0") } }, "code" : { "coding" : [ { "code" : "default", "system" : "detected_issue_codes" } ], "text" : null }, "context_episode_id" : UUID("e8f13f2b-1522-4a7f-afd5-3a0c0fe21a23"), "detail" : "some details", "encounter" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "encounter", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("459010ca-52fc-49d2-8fc3-7e60f4d1b2ab") } }, "identified_date_time" : ISODate("2018-08-02T10:45:16.000Z"), "implicated" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "device", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("59a5d6ed-b724-43cc-bfd7-b67028797df1") } }, "inserted_at" : ISODate("2024-03-18T14:40:12.559Z"), "inserted_by" : UUID("27f4a543-aae0-4575-b10c-ee4f4cb008f5"), "patient_id" : "5E0168F480B03462A33EFD0E13C419374E681C3C1280A407612715BC019C0904", "recorder" : { "display_value" : "СЕРГІЙ ОЛЕКСАНДРОВИЧ ПАВЛОВСЬКИЙ", "identifier" : { "type" : { "coding" : [ { "code" : "employee", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("eb794be3-e081-40ea-9ff7-e5e3f013b721") } }, "recorder_legal_entity" : { "display_value" : "Solute Med", "identifier" : { "type" : { "coding" : [ { "code" : "legal_entity", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("6e5a53bc-9c71-4c66-9cdc-37560d6dbf49") } }, "status" : "mitigated", "subject" : { "display_value" : null, "identifier" : { "type" : { "coding" : [ { "code" : "device", "system" : "eHealth/resources" } ], "text" : null }, "value" : UUID("af3230f9-7d58-432e-be54-5175f96034ff") } }, "updated_at" : ISODate("2024-03-18T14:40:12.559Z"), "updated_by" : UUID("27f4a543-aae0-4575-b10c-ee4f4cb008f5") }